Structural Steel Column NanoPrep trial
Sugar

Structural Steel Column Corrosion Protection

7 Year NanoPrep Trial

Download Case Study
Industry: Sugar
Application: Surface preparation and coating
Products: NanoPrep
Customer Location: Qld, Australia
Application Date: Sept 2017 – Jul 2024

2017

In September 2017 we applied two coats of NanoPrep to the base of a structural steel column at a sugar mill. The column forms part of the structure of a sugar conveyor located within 20 feet of a salt water river. The whole structure is suffering severe weathering and corrosion damage, and it has been deemed impractical to abrasive blast and coat the conveyor.

The client tested NanoPrep on a small, corroded steel area to see if it could provide a suitable surface for a protective top coat.

2018 to 2019

An inspection was completed in May 2018. The application had seen no deterioration and system was in good condition.

An additional inspection was completed in August 2019 where there was clear evidence of rust on the coating, however this was from the salt water and rust dripping onto the base from above. Once cleaned the application was found to be completely intact and the adhesion of the NanoPrep was excellent.

The system was not drummy at all when tapped with a screw driver and the base remains completely protected.

2020 to 2021

A third Inspection of the application was conducted in March 2020. Again, heavy rust had formed on the application from the structure above. ReziSafe’s Acidsafe 80 was used to clean the rust as best as possible (some rust could not be removed) which showed the application still in excellent condition. When tapped with a screw driver the coating was very solid and continues to protect against the harsh conditions.

A fourth inspection of the application was conducted in November 2021. Again, heavy rust had formed on the application from the structure above. ReziSafe’s Acidsafe 80 was used to clean the rust as best as possible and once removed showed the application still in excellent condition. The coating was still in very good condition and continues to protect against the harsh conditions.

Midway through 2024, 7 years on, the coating is still tightly bonded to the surface and protected against further corrosion, even in the harshest salt water environment.

2024

Midway through 2024, 7 years on, the coating is still tightly bonded to the surface and protected against further corrosion, even in the harshest salt water environment.

Project Specification

Item Detail
Industry Sugar
Application Structural steel column — base corrosion
Surface condition Significant corrosion at column base
Surface preparation Hand tool clean — no blasting
Application method Brush application
NanoPrep system NanoPrep rust primer + compatible topcoat
Key requirement In-situ treatment without production disruption